User`s manual

137
How to configure: After selecting Ping Failure event type, the system will turn
Relay Output to short state and continuously ping the target device. When the
ping failure occurred, the switch will turn the Relay Output to open state for a
period of Reset Time.
After the Reset Time timeout, the system will turn the Relay Output to close state.
After the Hold Time timer is timeout, the switch system will start ping the target
device.
Ex: Reset Time is 5 sec, Hold Time is 50 sec.
If the ping failure occurred, the switch system will turn Relay output to open
state to emulate power switch off for 5 sec periods. After Reset Time timeout,
the Switch system will start ping target device after 50 sec periods. The period
time is for target device system booting. During the period, the switch system will
not ping target device until Hold Time is timeout.
Event Type: Super Ring Failure
Select Super Ring Failure. When the Rapid Super Ring topology is changed, the
system will short Relay Out and lengthen DO LED.
Once you finish configuring the settings, click on Apply to apply your
configuration.