User`s manual

135
Event Type: DI State
DI Number: Select DI 1 or DI 2. Select which DI you want to monitor.
DI State: High or Low. Select the power voltage you want to monitor.
How to configure: Select the DI Number you want to monitor and DI State, High
or Low. For example: When DI 1 and High are selected, it means when DI 1 is
pulled high, the system will short Relay Output and light DO LED.
Event Type: Dry Output
On Period (Sec): Type the period time to turn on Relay Output. Available range of
a period is 0-4294967295 seconds.
Off Period (Sec): Type the period time to turn off Relay Output. Available range
of a period is 0-4294967295 seconds.
How to configure: Type turn-on period and turn-off period when the time is
reached, the system will turn on or off the Relay Output. If you connect DO to DI
of the other terminal unit, the setting can help you to change DI state. If you
connect DO to the power set of other terminal units, this setting can help you to
turn on or off the unit.
How to turn On/Off the other device: Type “1” into the “On period” field and “0”
into “Off Period” field and apply the setting, then it t will be trigger to form as a
close circuit.
To turn off the relay, just type “0” into the “On period” field and “1” into “Off
Period” field and apply the setting, the relay will be trigger to form as an open
circuit.
This function is also available in CLI, SNMP management interface. See the
following setting.
Turn on the relay output