User guide
7
6640-2205
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
EMC
ESD EN 61000-4-2 Enclosure contact ± 6 kV
Enclosure air ± 8 kV
RF field AM modulated EN 61000-4-3 Enclosure 10 V/m 80 – 800 och 1000 – 2100 MHz
20 V/m 800 – 1000 MHz
5 V/m 2100 – 2500 MHz
1 V/m 2500 – 2700 MHz
Fast transient EN 61000-4-4 Signal ports ± 2 kV
Power ports ± 2 kV
Surge EN 61000-4-5 Signal ports ± 2 kV line to earth, ± 2 kV potential difference
Power ports ± 2 kV line to earth, ± 2 kV line to line
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency magnetic field EN 61000-4-8 Enclosure 1000 A/m, 50 Hz
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m
Voltage dips and interruption EN 61000-4-29 DC power ports Voltage interruption - 3 x 30 s within 5 minutes:
19V to 0 V & 62.4 V to 0V
Power supply variation - 3 x 1 minute
30% increase and 25% reduction
Radiated emission EN 55022 Enclosure Class B
FCC part 15 Class B
IEC 60945 Complying with the limit line
Conducted emission EN 55022 Signal ports Class B
EN 55022 DC power ports Class B
IEC 60945 Complying with the limit line
Dielectric strength EN 60950-1 Signal port to
other isolated
ports
1.5 kVrms 50 Hz 1 min
Power port to
other isolated
ports
1.5 kVrms 50 Hz 1 min
Environmental
Temperature Operating –40 to +70ºC
Storage &
Transport
–50 to + 85ºC
Humidity Operating 5 to 95% relative humidity
Storage &
Transport
5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa
Service life Operating 10 year
Vibration IEC 60068-2-6 Operating
1 mm, 3 – 13.2 Hz
0.7 g, 13.2 – 100 Hz
1.5 g, 5.5 – 30 Hz
0.42 mm, 30 – 50 Hz
4.2 g, 50 – 500 Hz
IEC 60068-2-64 Operating 0.23 g, 3 – 2000 Hz
Shock IEC 60068-2-27 Operating
All directions: 2 g, 11 ms
Z-axis: 30 g, 11 ms
Bump IEC 60068-2-29 Operating 2 g, 11ms
Packaging
Enclosure UL 94 Aluminium Flammability class V-1
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight 0.6 kg
Degree of protection IEC 529 Enclosure IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail