User guide

4
6640-2205
WARNING– SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR 
DIVISION 2.
WARNING– DO NOT OPEN WHEN ENERGIZED.
WARNING– DO NOT DISCONNECT EQUIPMENT UNLESS AREA IS KNOWN TO 
BE NON-HAZARDOUS.
AVERTISSEMENT – RISQUE D'EXPLOSION.NE PAS DÉBRANCHER TANT QUE LE 
CIRCUIT EAT SOUS TENSION,Á MOINS QU'IL NE S'AGISSE 
D'UN EMPLACEMENT NON DANGEREUX.
SPECIAL CONDITION OF USE:
This equipment shall be installed in compliance with the enclosure,mounting,spacing and 
segregation requirements of the ultimate application,including a tool removable cover.
Note.Fibre Optic Handling
Fibre optic equipment needs special treatment.It is very sensitive to dust and dirt.If the 
fibre will be disconnected from the unit the protective hood on the transmitter/receiver 
must be connected.The protective hood must be kept on during transportation.The fibre 
optic cable must also be handle the same way.
Cleaning of the optical connectors
In the event of contamination,the optical connectors should be cleaned by the use of 
forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
Methyl-,ethyl-,isopropyl- or isobutyl-alcohol,Hexane,Naphtha
Maintenance
No maintenance is required,as long as the unit is used as intended within the specified 
conditions.