User guide
6
6643-2250
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
ESD EN 61000-4-2 Enclosure Contact: ±6 kV
Air: ±8 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Signal ports ±2 kV
Earth port ±1 kV
Surge EN 61000-4-5 Power port L-E: ±0.5 kV, 12 Ω, 9 μF
L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±2 kV, 42 Ω, 0.5 μF
L-E: ±2 kV, 12 Ω, 9 μF
L-L: ±1 kV, 12 Ω, 9 μF
Signal ports L-E: ±1 kV, 2 Ω
L-E: ±2 kV, 42Ω, 0.5 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m
Radiated RF immunity EN 61000-4-3 Enclosure 10 V/m @ (80 – 800) MHz
20 V/m @ (800 – 1000) MHz
10 V/m @ (1400 – 2100) MHz
5 V/m @ (2100 – 2500) MHz
1 V/m @ (2500 – 2700) MHz
1 kHz sine, 80% AM
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Signal ports 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission EN 55022 Enclosure Class A
FCC Part 15 Class A
Conducted RF emission EN 55022 Power port Class B
Signal ports Class B
Dielectric strength EN 60950-1 Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Signal ports to all
other ports
1.5 kVrms, 50 Hz, 1 min
Environmental
Temperatures Operating –40 to +70°C (–40 to +158°F)*
Storage and transport –50 to +85°C (–58 to +185°F)
Humidity Operating 5 to 95 % relative humidity
Storage and transport 5 to 95 % relative humidity
Altitude Operating 2 000 m / 70 kPa
Service life Operating 10 year
Reliability prediction (MTBF) MIL-HDBK- 217F Operating 615 000 hours
Vibration IEC 60068-2-6
(sine)
Operating 3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**
Shock IEC 60068-2-27 Operating 30 g, 11 ms
100 g, 6 ms**
Bump IEC 60068-2-27 Operating 10 g, 11 ms
Packaging
Enclosure EN 60950-1 Zinc Fire enclosure
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight 0.7 kg
Degree of protection EN 60529 Enclosure IP 40
Cooling Convection
** Refer to “Safety” section.
** Might require Ethernet cables to be fastened close to the unit.