GDW-11 GDW-11 GDW-11 GSM/GPRS Modem GDW-11 485 GSM/GPRS Modem with RS-485 www.westermo.
Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Safety ! Before using this unit: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. Hazardous voltages may occur within this unit when connected to a power supply. Prevent access to hazardous voltages by disconnecting the unit from its power supply.
General Remember to follow any special regulations and warnings in force in any area and never use the unit whenever it’s forbidden to use it. Do not use the unit when it may cause interference or danger. A wireless device exposed to interference above specified limits could result in deteriorated performance. Hospitals or other Medical environment Do not use the unit in a medical environment such as health care facilities. Follow any regulations or rules that instruct you to not use the unit.
For Vehicles equipped with an airbag An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If in-vehicle wireless equipment is improperly installed and the air bag inflates, serious injury could result. Blasting areas Do not use the unit where blasting is in progress or in “blasting areas”. Observe restrictions and follow any regulation or rules.
Agency approvals and standards compliance Type Approval / Compliance EMC EN 61000-6-2, Immunity industrial environments EN 55024, Immunity IT equipment EN 61000-6-3, Emission residential environments FCC part 15 Class B EN 50121-4, Railway signalling and telecommunications apparatus IEC 62236-4, Railway signalling and telecommunications apparatus Safety EN 60950, IT equipment R&TTE Article 3.1b Article 3.
ATEX Information (Applicable for GDW-11 EX / GDW-11 485 EX only) General This unit is intended for use in Zone 2 hazardous location only. Marking II 3 G Ex nA IIC T4 Gc SPECIAL CONDITION WARNING – DO NOT SEPARATE WHEN ENERGIZED Indicate that this unit complies with relevant European standards that are harmonised with the 94/9/EC Directive (ATEX). II 3 G Ex nA IIC T4 Gc SPECIAL CONDITION 6615-2203 Equipment group II.
Ratings and safety control drawing, GDW-11 EX Power Ambient temperature Maximum surface temperature Ingress protection (IP) Installation spacing (12 – 48) VDC; 350 mA –25ºC ≤ Ta ≤ +50ºC Temperature class T4 (max 135ºC ) IP21 Minimum 25 mm above / below and minimum 10 mm left / right Antenna Position Direction / description 1 Shield Input / Output values Max RF power: 2 watt Data rate: CSD: up to 14.4 kbit/s GPRS: up to 85.
Ratings and safety control drawing, GDW-11 485 EX Power Ambient temperature Maximum surface temperature Ingress protection (IP) Installation spacing (12 – 48) VDC; 350 mA –25ºC ≤ Ta ≤ +50ºC Temperature class T4 (max 135ºC ) IP21 Minimum 25 mm above / below and minimum 10 mm left / right Antenna Position Direction / description 1 Shield Input / Output values Max RF power: 2 watt Data rate: CSD: up to 14.4 kbit/s GPRS: up to 85.
GDW-11 EX / GDW-11 485 EX Special condition for safe use Ambient temperature: This unit is designed for use in extreme ambient temperature conditions according to the following: –25ºC ≤ Ta ≤ +50ºC Installation in an apparatus cabinet: This unit requires installation in an Ex certified apparatus cabinet suitable for the area of use and providing a degree of protection of at least IP54.
Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model GSM modem GDW-11, GDW-11 EX, GDW-11 485, 3615-0001, -5001, -0030, -5030 GDW-11 485 EX Art no is in conformity with the following EC directive(s).
Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test ESD EN 61000-4-2 Description Enclosure contact Enclosure air Enclosure Test levels ± 6 kV ± 8 kV 20 V/m 80% AM (1 kHz), 80 – 2000 MHz 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz ± 2 kV ± 2 kV ± 2 kV line to earth, ± 2 kV line to line ± 2 kV line to earth, ± 1 kV line to line ± 2 kV line to earth, ± 2 kV line to line 10 V 80% AM (1 kHz), 0.15 – 230 MHz 10 V 80% AM (1 kHz), 0.15 – 230 MHz 100 A/m, 50 Hz, 16.
Description The GDW-11 provides a reliable data communication link over GSM/GPRS networks. The unit has been designed for use in industrial data communication applications and has several features that are not normally present on standard GSM modems. The GDW-11 is a DIN-rail mounted modem with RS-232 interface in a 9-pin D-sub. The GDW-11 485 also has an RS-422/485 interface in screw terminal block.
Functional description GDW-11 / GDW-11 EX 5-pos screw terminal RF Interface SMA connector SIM connector transient protection SIM card connector LED driver LED’s RS-232 Drivers and protection GSM Engine 9-pos D-sub DIP switches 2-pos screw terminal Isolated power supply GDW-11 485 / GDW-11 485 EX LED’s 4-pos screw terminal 9-pos D-sub 2-pos screw terminal 14 LED driver RS-485 Drivers and protection GSM Engine RS-232 Drivers and protection RF Interface SMA connector SIM connector tran
Interface specifications Power Rated voltage 12 to 48 VDC Operating voltage 10 to 60 VDC Rated current 350 mA @ 12 VDC 150 mA @ 24 VDC 75 mA @ 48 VDC Rated frequency Inrush current I2t DC 0.05A2s Startup current* 0.75A peak Polarity Reverse polarity protected Connection Detachable screw terminal Connector size 0.2 – 2.
RS-422/485 Electrical specification Data rate Data format Protocol Retiming Turn around time Transmission range Settings Protection Isolation to Connection Connector size Shielded cable Miscellaneous EIA/TIA-485 ITU V.11 2-wire or 4-wire twisted pair 1 200 bit/s – 115.2 kbit/s 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
Connections GDW-11 SIM interface under lid Antenna interface LED Indicators (for details see page 19) RS-232 screw terminal R T PW NE RD TD Direction In Out In Out – Description TD RD DTR DSR SG 4 5 123 5-position No. 1 No. 2 No. 3 No. 4 No. 5 1 2 Power connection screw terminal 2-position No. 1 No. 2 Direction In In Description – VDC + VDC RS-232 D-sub 9-position No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No.
Connections GDW-11 485 SIM interface under lid Antenna interface LED Indicators (for details see next page) RS-232 D-sub DIP-switch S2 termination see page 20–21 Direction Out Out In In – Out In Out Out Description Data Carrier Detect (DCD) Receive Data (RD) Transmit Data (TD) Data Terminal Ready (DTR) Signal ground (SG) Data Set Ready (DSR) Request To Send (RTS) Clear To Send (CTS) Ring Indicator (RI) 12 4 12 3 9-position No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No.
LED Indicators LED Status Description PWR ON In service OFF Out of service ON Modem switched ON, Not registered on network OFF Modem switched OFF Slow Flash Modem switched ON, registered on the network Quick Flash Modem switched ON, registered on the network, communication in progress ON Data received on the RS-232 or RS-485 port OFF No data received on the RS-232 or RS-485 port ON Data transmitted on the RS-232 or RS-485 port OFF No data transmitted on the RS-232 or RS-485 port ON
DIP-switch settings DIP-switches under the lid on top of the unit ! Before DIP-switch settings: Warning! Do not open connected unit Hazardous voltages may occur within this unit when connected to a power supply. Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top of the unit is removed. To activate DIP-switches Advanced mode needs to be enabled.
S1 Selection of DTE interface, only in GDW-11 485 / GDW-11 485 EX ON RS-232 interface ON 1 2 3 4 ON 1 2 3 4 1 2 3 4 RS-422/485 interface 4-wire full duplex RS-485 interface 2-wire half duplex S2 DIP-switch RS-422/485 termination, only in GDW-11 485 / GDW-11 485 EX ON ON Termination of R in 4-wire connection No termination 1 2 3 4 ON 1 2 3 4 1 2 3 4 Termination of both T and R in 2-wire connection ON 1 2 3 4 Termination of both T and R in 4-wire connection S3 Selection of data rate, only in G
RS-422/485 general advice 4-wire termination R+ R– T+ T– GDW-11 485 GDW-11 485 EX R– R+ T– T+ R– R+ T– T+ B’ A’ B A =Termination Slave unit Slave unit Slave unit 2-wire termination T+ T– Max 0.3 metre GDW-11 485 GDW-11 485 EX T- T+ T- T+ B A =Termination Slave unit Slave unit Slave unit Termination recommendations The RS-422/485 line must be terminated. In the GDW-11 485 / GDW-11 485 EX, the termination is combined with fail-safe functionality.
Installation Mounting / Removal Before mounting or removing the unit: ! Warning! Do not open connected unit Hazardous voltages may occur within this unit when connected to a power supply. Warning! Prevent access to hazardous voltages by disconnecting the unit from its power supply. Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
SIM card The SIM card is accessable under the lid on top of the unit.The SIM card is needed for full operation of the unit. ! Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top of the unit is removed. ! Warning! Do not open connected equipment. Hazardous voltage may occur within this unit when connected to power supply.
Windows configuration tool GD-Tool The GD-Tool is a PC – application program with a graphical interface for easy configuration of the complex functions found in the GDW-11. Please refer to GD-Tool for a complete description of the functionality of the Windows program. Start up guide Follow the steps below to get the unit up and running in a simple application Default settings of the serial interface are: … AT+IPR=9600 9.6 kbit/s … AT+ICF=3,4 8 databits, no parity and 1 stop bit.
Configuration The GDW-11 can be configured from the local DTE interface. When the local interface is used the configuration can be made with AT-commands on the serial interface, or with a PC-based application configuration tool. Factory default settings can also be obtained by using a DIP switch locally. Standard mode is used for basic GSM modem functionality Advanced mode adds extended command set and functions. See AT+WOPEN.
+CPWD – Change password Syntax: AT+CPWD= , , Parameters: "PS" SIM lock facility with a 8 digits password. "SC" PIN enabled ( = 1) / disabled ( = 0). "AO" BAOC (Barr All Outgoing Calls). “OI” BOIC (Barr Outgoing International Calls). “OX” BOIC-exHC (Barr Outgoing. International Calls except to Home Country). “AI” BAIC (Barr All Incoming Calls). “IR” BIC-Roam (Barr Incoming When Roaming outside Home Country). “AB” All Barring services.
+CSQ – Received signal strength Syntax: AT+CSQ. Response syntax: +CSQ: , Parameters: 0 1 2 to 30 31 99 –113 dBm or less. –111 dBm. –109 to –53 dBm. –51 dBm or greater. Not known. 0 1 2 3 4 5 6 7 99 BER < 0.2% 0.2% < BER < 0.4% < BER < 0.8% < BER < 1.6% < BER < 3.2% < BER < 6.4% < BER < BER > 12.8% Not known. 0.4% 0.8% 1.6% 3.2% 6.4% 12.8% &D – DTR control TSyntax: AT&Dn 0 The DTR signal is ignored. 1 Modem switches from data to command mode when DTR swtches from ON to OFF.
+ICF – Serial character format Syntax: AT+ICF = , Parameters: 0 1 2 3 4 5 6 Data bits – 8 8 8 7 7 7 0 1 2 3 4 Odd. Even. Mark. Space. None. Parity bit – 0 1 0 0 1 0 Stop bit(s) – 2 1 1 1 1 1 +IFC – Serial flow control Syntax: AT+IFC = , Parameters: 0 None. 2 RTS. 0 None. 2 CTS.
Q – Result code suppression Syntax: ATQ Parameters: 0: DCE transmits result codes. 1: Result codes are suppressed and not transmitted.
Response syntax: +WOPEN: [,[]] Parameters: 0: Stop the Open-AT embedded application. If the product was running, it resets. 1: Start the Open-AT embedded application. If the product was stopped, it resets. 2: Get the Open AT library versions. 3: Erase the objects flash of the Open-AT embedded application. 4: Erase the Open-AT embedded application. 5: Suspend (in WAVECOM software kernel) the Open AT embedded application tasks.
+WRST – Reset command Syntax.
Application examples … GDW-11 connected to GDW-11 with DTR signal call GSM Network Configure the units AT+CPIN=xxxx AT&F AT&W If PIN code required Set the unit to factory default Store default settings Set up the connection – The dialling modem AT+CPBS=”SM” AT+CPBW=1,”nnn” AT&S0 AT%D1 AT&W Switch DTR from OFF to ON Select phonebook as memory storage (this is default) Store the number of the remote modem in the dialling GDW-11 Set DSR signal always high (if this signal is used to trig the DTR) Activate
… GDW-11 connected via CSD-V32 to analogue modem GSM Network PSTN Network Configure the GDW-11 AT+CPIN=xxxx AT&F AT+CBST=7,0,1 AT&W If PIN code required Set the unit to factory default Set the bearer to V.
… GDW-11 connected via CSD-V.110 to ISDN adapter GSM Network ISDN Network Configure the GDW-11 AT+CPIN=xxxx AT&F AT+CBST=71,0,1 AT&W If PIN code required Set the unit to factory default Set the bearer to V.110 protocol at 9600 bit/s Save settings Configure the IDW-90 AT&F AT**PROT=0 AT**BRN=4 AT**V110LLC=1 AT%B4 AT&W Set the unit to factory default Set the B-channel protocol to V.110 Set line baudrate for V.110 to 9600 bit/s Set low layer compatibility to send detailed information about V.
… GDW-11 sending text message with SMS by activating DTR signal GSM Network Configure the GDW-11 AT+CPIN=xxxx AT&F AT+CMGW=”0762342489” Alarm text message +CMGW: 1 AT&S0 AT%D2 AT&W If PIN code required Set the unit to factory default Store the destination phone number and the text message in the SIM card Its important that location 1 is used (the modem should respond with +CMGW: 1). If index is more than 1, delete previously stored message in location 1 with AT+CMGD= 1,0 and then try again.
… GDW-11 communicates via GPRS and a PC to public server on Internet GPRS Network Internet Configure the GDW-11 AT+CPIN=xxxx AT&F AT+CGATT=1 AT+CGDCONT=1,”IP”,”xxx” AT&W If PIN code required Set the unit to factory default Make an attach (register) to the GPRS network Define the PDP context with APN=”xxx” Save settings Connect the GDW-11 to the PC and configure a standard “remote dial-up” connection in the Windows environment.
… G DW-11 communicates via GPRS to another GDW-11 with TCP socket connection. This example uses SIM cards with fixed IP addresses. GPRS Network Configure the GDW-11 with a terminal (both units) AT+WOPEN=1 AT+CPIN=xxxx AT&F AT+CGATT=1 AT&W Enable Advanced mode.
… GDW-11 485, two wire half duplex GDW-11 485 GSM Network 1 Termination 2 3 4 In this application the GDW-11 485 is set to communicate with a number of units with RS-485 interface. The communication is 2 wire half duplex at 38 400 bit/s. Configure the GDW-11 485 AT+CPIN=xxxx AT&F AT&W S1:4 ON S2:1,2 ON S3:1,3 ON If PIN code required Set the unit to factory default Store default settings Select 2-wire RS-485 half duplex Termination / Failsafe active 38.
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com Westermo Web site: www.westermo.com United Kingdom Westermo Data Communications Ltd Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580‑585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Germany Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.