User guide

10
6622-2231 29000448
Interface specifications
Power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current (max) 1500 mA @ 12 VDC 
Rated frequency DC
RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s – 115.2 kbit/s
Data format 7 or 8 data bits,Odd,even or none parity,1 or 2 stop bits
Protocol Transparent,optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required 
Conductive housing Yes
Number of ports 1
Ethernet TX
Electrical specification IEEE std 802.3.2005 Edition
Data rate 10 Mbit/s,100 Mbit/s,manual or auto
Duplex Full or half,manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required,except when installed in Railway applications as signalling 
and telecommunications apparatus and located close to rails.*
Conductive housing Yes
Number of ports 4
* To minimise the risk of interference,a shielded cable is recommended when the cable is located inside 3 m 
boundary to the rails and connected to this port.
The cable shield should be properly connected (360º) to an earthing point within 1 m from this port.
This earthing point should have a low impedance connection to the conductive enclosure of the apparatus  
cabinet, or similar,where the unit is built-in.This conductive enclosure should be connected to the earthing  
system of an installation and may be directly connected to the protective earth.