User's Guide

Ibex-RT-310 and Ibex-RT-320 Series User Guide
Westermo Network Technologies 27
Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068
-
2
-
1
EN 60068-2-2
EN 60068-2-14
Operational
-
40 to +7
0
°C (
-
40 to +1
58
°F)
2
Storage and
transport
-
55 to
+85°C (
-
67 to +185°F)
H
umidity
EN 60068
-
2
-
30
Operational
5
-
95% relative humidity
Storage and
transport
Altitude
Operational
3
000
m
MTBF
IEC TR 62380
307027
hours
Vibration
MIL STD 810,
M514.7
(sine)
Operational
5 to
1
0 Hz,
5.08
mm
p
-
p
10 to 200 Hz, 2 g
20 sweep cycles in each axis, 0.9
octave/min
EN
60068
-
2
-
64
(random)
Operational,
endurance test
11.44
m/s
2
random,
5 to 150 Hz, 3 x 5 h
2.3 m/s
2
random,
5 to 2000 Hz, 3 x 4 h
Shock
3
EN 60068
-
2
-
27
Operational
10
0
m/s
2
, 30
ms, 3 x 6
shocks
(half sine)
MIL STD 810
,
M516.7
2
0 g
, 11 ms, 3 x 6 shocks
(saw tooth)
Weight
1
100
gr
Degree of protection
EN 60529
Enclosure
IP66
4
Cooling
Convection
Pollution degree
EN 62368
-
1
PD2
Conformal coating
type
IPC
-
A
-
610
Electronic
modules
AR (
Acrylic
)
Table 15 Environmental and mechanical conditions
2
Refer to "Safety Information" chapter regarding touch temperature
3
The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation
applies to the Antenna cables
4
Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the
unit) and tightened to the specified torque