5.2 Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000
-
4
-
2
Enclosure
Contact: ±
6
kV
Air: ±8 kV
Fast transients
EN 61000
-
4
-
4
DC pow
er port
± 2 kV, direct coupling
Ethernet ports
± 2 kV, capacitive coupling clamp
Antenna ports
Surge
EN
61000
-
4
-
5
DC power port
L
-
E: ± 1 kV, 12
Ω
, 9
μ
F, 1.2/50
μ
s
L-E: ± 2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ± 1 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ± 2 kV, 42 Ω, 0,5 μF, 1.2/50 μs
Ethernet ports
L
-
E: ±
1
kV, 2 Ω,
18uF,
1.2/50 μs
Antenna ports
Power
frequency
magnetic field
EN 61000
-
4
-
8
Enclosure
3
00 A/m continues,
DC, 16.7 Hz, 50
Hz, 60 Hz
Pulsed magnetic
field
EN 61000
-
4
-
9
Enclosure
300 A/m
Radiate
d RF
immunity
EN 61000
-
4
-
3
Enclosure
20 V/m, 80% AM (1kHz) at 80 MHz
to 2.7 GHz
3 V/m, 80% AM (1kHz) at 2.7 GHz to
6 GHz
30 V/m, PM 200 Hz square at 380
MHz to 385 MHz
30 V/m, PM 200 Hz square at 390
MHz to 395 MHz
Conducted RF
immunity
EN 61000
-
4
-
6
DC po
wer port
10 V,
80% AM (1kHz)
from
0.15 to 80
MHz
Ethernet ports
Antenna ports
Radiated RF emission
CISPR 16
-
2
-
3
Enclosure
Class B
FCC Part 15 B, Class B
Conducted RF
emission
CISPR 16
-
2
-
1
DC power port
Ibex
-
RT
-
31
0
/320
-
LV
:
Class B
Ibex-RT-320-HV: Class A
Ethernet
ports
Insulation resistance
EN 50155
DC power port
to all other ports
> 100 MOhm
Dielectric strength
EN 50155
DC p
ower port
to all other ports
Ibex
-
RT
-
31
0
/320
-
LV: 750 VDC,
6
0 s
Ibex-RT-320-HV: 2250 VDC, 60 s
Table 14 EMC and electrical conditions