User's Guide

Ibex-RT-310 and Ibex-RT-320 Series User Guide
Westermo Network Technologies 16
No.
Description
1
Antenna
2
1000Base
-
T
3
Grounding point
4
Power
Figure 7 View to interface ports
3.4
Connector Information
3.4.1
Power Input Connection
M12 A
-
coded 4
-
pin male
power
connector according to IEC 61076
-
2
-
101
Marking
Position
Direction
Description
DC
1
+DC
Positive
terminal
2
-
3
-
DC
Negative
terminal
4
-
Housing
Shield
Chassis of product (ground)
Table 4 Power input connection
NOTE
If device is powered by PoE, the protective dust cap which is part of the delivery
must be closed to protect the power interface from water or dust ingress.
3.4.2
Ethernet Ports
The product includes two Ethernet ports X1 and X2 which supports auto-negotiated 10 Mbit/s, 100
Mbit/s and 1000 Mbit/s operation. Automatic MDI/MDIX crossover is supported for 10BASE-T,
100BASE-T, 1000BASE-T operation.
M12
D
-
coded
4
-
pin
fe
male
Ethernet
connector according to IEC 61076
-
2
-
10
9
Marking
Position
Direction
Description
X1 / X2
1
In / Out
DA
+
2
In / Out
DA
-
3
In / Out
DB
+
4
In / Out
DB
-
5
In / Out
DD+
6
In /
Out
DD
-
7
In / Out
DC
-
8
In / Out
DC+
Housing
Shield
Chassis of product (ground)
Table 5 Ethernet connection
1
4
2
3
2
1
8
7
3
4
5
6