Service manual
GENERATOR
AC
VOLTAGE
CONNECTIONS
AC
VOLTAGE
CONNECTIONS
NOlE
The frame ground wire (white/green) must be prop-
erly positioned when changing the AC output configuration
of
the AC terminal block. For making connections to the AC
terminal block, use terminal
ends·for
114
inch studs that will
accept multi strand copper wire
siW1 for the amperage rating
from the hot lead connection.
The
frame ground wire is white
or white with a green strip.
It
connects between the neutral
stud and the generator frame.
Generator
Frequency
1.
Frequency is a direct result
of
engine/generator speed:
1800 rpm =
60
hertz; 1500 rmp =
50
hertz.
2.
To
change generator frequency., follow the step's below:
Configure the AC terminal block for the desired voltage
frequency as shown. Ensure that the case ground wire is
connected to the correct terminal block neutral ground
stud.
NOTE:
The
white/green ground
wire
may
be
removed
in
those
installations
where
the
AC circuit has a separate neutral and
ground
circuit.
This
will prevent
the
unit
from
being a
ground
source
in
the
vessel.
120/240V.
~OHz
o 0
120V60Hz
230V50Hz
115V
50Hz
o 0
L1
L1
L2
'I
N
L1
A
JUMPER
IS
REQUIRED
BETWEEN
LOAD
CONNECTIONS.
0
1Jt)
4
-=
®
Engines & Generators
64
0
L1
N
0
ILLUSTRATION
SHOWS
230V-50Hz
CONNECTIONS.