Operator`s manual
5.
Adjust the alternator and water pump drive belt tension,
if
required.
6.
Adjust the engine's no-load speed,
if
required (Hertz). Please note that this adjustment
is
not a
warrantable adjustment during or after the unit's break
in.
7.
Lubricate the ball joint linkage between the run solenoid and the throttle arm.
Servicing
After
Every 100 Hours of Operation
I. Change the engine's lube oil and filter.
2.
Adjust the alternator and water pump drive belt tension,
if
required.
3.
Lubricate the ball joint linkage between the run solenoid and the throttle arm.
4.
Inspect siphon-break assembly for proper operation (when installed).
Servicing
After
Every
250
Hours of Operation
Replace the fuel filter elements in the electric fuel lift pump and in the engine-mounted filter assembly.
Servicing
After
Every 500 Hours of Operation
* I. Torque the cylinder head hold-down bolts.
*2.
Adjust the valve clearances.
3.
Drain, flush, and refill the fresh water cooling system. For an illustration showing the heat
exchanger and block drain locations, see model photos with call outs at the beginning
ofthis
manual.
*4.
Check the condition
of
the starter motor drive pinion; lubricate pinion.
5.
Check the resistance
of
the glow plus. Check circuit operation. 1.0 -
1.2
ohms.
6.
Check raw water pump for internal wear. Examine the pump's cover, cam and internal housing.
Replace worn parts as needed. Check for leaks at seals or gaskets and make repairs as needed. Do not
neglect.
7.
Check external and internal condition
of
the water injected exhaust elbow. Inspect exhaust and water
passages in the elbow. Remove any carbon and/or corrosion build
up.
Replace the elbow should its
condition be questionable.
WESTERBEKE
GENERATORS
82