Service manual

SPECIFICATIONS
WESTERBEKE
20
KW
BEDA
GENERATOR
ELECTRICAL
SYSTEM
AC
GENERATOR
(3
Phase)
Starting
Battery
Battery
Capacity
DC
Charging
Altemator
Starter
Starting
Aid
DC
No-Load
Current
DC
Cranking
Current
12-Volt,
(-)
negative
ground
400
-
600
Cold
Cranking
Amps
(CCA)
51
Amp
rated,
belt-driven
12-Volt,
Reduction
Gear,
3
KW
Glow
plugs,
sheathed
type
±
2%
of
rated
Amps
250
-
300
Amps
(engine
cold)
AC
GENERATOR
(SINGLE
PHASE)
General
-
Single
Phase
Voltage
-
Single
Phase
Voltage
regUlation:
Frequency
regulation:
Rating
(Volts
AC)
Brushless,
four-pole,
revolving
field
Sealed
lubricated
single
bearing
design.
Reconnectable
single
phase
for
1201240
volts
with
solid
state
voltage
regulator.
120
or
120/240
Volts
-
60
Hertz
230
Volts
-
50
Hertz
±
2%
no
load
to
full
load.
0.30
Hertz
no
load
to
full
load.
20
KW
-
60
Hertz
(1800
rpm)
120
Volts
166
Amps
1201240
Volts
166183
Amps
16
KW
-
50
Hertz
(1500
rpm)
230
Volts
72.7
Amps
General
- 3
Phase
Brushless
six
pole,
revolving
field.
20.0
KW
-
60
Hertz
Sealed
lubricated
single
bearing
16.0
KW
-
50
Hertz
design.
12
Lead
reconnectable
for
low
voltage
WYE,
high
voltage
Delta.
Solid
State
voltage
regulator
with
protection
circuitry.
Voltage
- 3
Phase
Low
voltage
WYE
208
volts
(60
Hertz)
High
voltage
WYE
480
volts
DELTA
240
volts
Voltage
- 3
Phase
High
voltage
WYE
380
volts
(50
Hertz)
DELTA
230
Volts
Amperage
- 3
Phase
Low
voltage
WYE
70
Amps
(60
Hertz)
High
voltage
WYE
35
Amps
DELTA
60
Amps
Amperage
- 3
Phase
High
voltage
WYE
30.4
Amps
(50
Hertz)
DELTA
52.5
Amps
GENERATOR
COOLING
Air
Requirements
425
cfm
(12.74
cmm)-
(60
Hertz
at
1800
RPM)
Note:
Increase
air
supply
15%
for
50
Hertz
operation
1500
rpm
Engine
Combustion
Air
81.0
cfm
(2.29
cmm)
Requirements
(60
Hertz
at
1800
RPM)
Engines & Generators
63