Service manual
GENERATOR
Ae
VOLTAGE
CONNECTIONS·
AC
VOLTAGE
CONNECTIONS
,NOTE:
The frame ground wire (white/green) must be prop·
erly positioned when changing the
AC
output configuration
of
the AC terminal block. For making connections to the
AC
terminal block, use terminal ends for 1/4 inch studs that will
accept multi strand copper wire sized for the amperage rating
from the hot lead connection. The frame ground wire is white
or white with a green strip.
It
connects between the neutral
stud and the generator frame.
BE
SINGLE
PHASE
Generator
Frequency
1.
Frequency is a direct result
of
engine/generator speed:
1800 rpm =
60
hertz; 1500 rmp =
50
hertz.
2.
To
change generator frequency, follow the steps below:
Configure the
AC
terminal block for the desired voltage
frequency as shown above. Ensure that the case ground
wire is connected to the correct terminal block neutral
ground stud.
NOTE:
The
white/green ground
wire
may be removed
in
those
installations where
theAC
circuit
has
a separate neutral and
ground
circuit.
This will prevent
the
unit
from
being a growid
source
in
the
vesseL
120/240
V -
60
Hz
120
V·
60
Hz
230V-50Hz
115
V·
50
Hz
o 0
o 0
o 0 o 0
L1
L1
L1
L2
il
Oil
I I
100
I
I I
I I
L--
••
--l
I I
100
i
I I
I I
~
__
--l
A
JUMPER
IS
REQUIRED
FOR
120V
-
60
Hz
---H--DIODES/LEDS
REGULATOR.
20
KW
BED
SHOWN
CIRCUIT
BREAKER
120V
•
240V
•
60Hz
.
Engines & Generators
53