Installation manual
ENGINE 
TROUBLESHOOTING 
The following troubleshooting table describes certain problems 
relating to engine service, the probable causes 
of 
these prob-
lems. and the recommendations to overcome these problems. 
Note: 
The engine s electrical system is protected by a 20 amp 
manual reset circuit breaker located on a bracket at the rear 
of 
the engine. 
Problem 
Probable 
Cause 
Verification/Remedy 
Start 
switch 
depressed, 
no 
start, 
no 
1. 
Battery 
Switch 
not 
on. 
1. 
Check 
switch 
and/or 
battery 
connections. 
panel 
indications. 
2. 
20-Amp 
circuit 
breaker 
tripped. 
2. 
Reset 
breaker; 
if 
breaker 
trips 
again, 
check 
preheat 
solenoid 
circuit 
and 
check 
circuit 
for 
shorts 
to 
ground. 
3. 
1 
O-Amp 
breaker 
tripped 
on 
3. 
Check 
voltage 
at 
and 
after 
breaker 
on 
preheat 
solenoid. 
preheat 
solenoid. 
4. 
Loose 
battery 
connections. 
4. 
Check 
(+) 
connection 
to 
starter 
solenoid 
and 
(-) 
connection 
to 
engine 
ground 
stud. 
Check 
battery 
cable 
connections. 
5. 
Preheat 
solenoid 
not 
operating. 
5. 
Check 
solenoid 
"S" 
terminal 
for 
voltage. 
Start 
switch 
depressed, 
no 
starter 
1. 
Connection 
to 
solenoid 
faulty. 
1. 
Check 
connection. 
engagement. 
2. 
Faulty 
switch. 
2. 
Check 
switch 
with 
ohmmeter. 
3. 
Faulty 
solenoid. 
3. 
Check 
that 
12 
volts 
are 
present 
at 
the 
solenoid 
connection. 
4. 
Loose 
battery 
connections. 
4. 
Check 
battery 
connections. 
5. 
Low 
battery. 
5. 
Check 
battery 
charge 
state. 
START 
switch 
is 
depressed; 
panel 
1. 
Poor 
connections 
to 
fuel 
solenoid. 
1. 
Check 
connections. 
indications 
OK; 
starter 
solenoid 
OK 
fuel 
solenoid 
not 
functioning. 
2. 
Defective 
fuel 
solenoid. 
2. 
Check 
that 
12 
volts 
are 
present 
at 
the 
(+) 
connection 
on 
the 
fuel 
run 
solenoid. 
Generator 
engine 
cranks, 
but 
does 
not 
1. 
Faulty 
fueling 
system. 
1. 
Check 
that 
fuel 
valves 
are 
open. 
start, 
fuel 
solenoid 
energized. 
1a. 
Switch 
to 
combine 
house 
and 
start 
batteries. 
1 
b. 
Check 
batteries. 
1 
c. 
Fuel 
lift 
pump 
at 
injection 
pump 
may 
be 
clogged. 
2. 
Preheat 
solenoid 
faulty. 
2. 
Check 
solenoid. 
3. 
Low 
battery. 
3. 
Switch 
to 
combine 
all 
batteries. 
3a. 
Replace 
batteries. 
Battery 
runs 
down. 
1. 
Oil 
Pressure 
switch. 
1. 
Observe 
if 
panel 
lights 
are 
activated 
when 
engine 
is 
not 
running. 
Test 
the 
oil 
pressure 
switch. 
2. 
High 
resistance 
leak 
to 
ground. 
2. 
Check 
Wiring. 
Insert 
sensitive 
(0 
-
.25 
amp) 
meter 
in 
battery 
lines. 
(Do 
not 
start 
engine.) 
Remove 
connections 
and 
replace 
after 
short 
is 
located. 
3. 
Low 
resistance 
leak. 
3. 
Check 
all 
wires 
for 
temperature 
rise 
to 
locate 
the 
fault. 
4. 
Poor 
battery 
connections. 
4. 
Check 
cable 
connections 
at 
battery 
for 
loose 
connections, 
corrosion. 
5. 
Battery 
charger 
not 
charging 
.. 
5. 
Check 
connections,Test 
battery 
charger 
in 
control 
box. 
Battery 
not 
charging 
1. 
DC 
charge 
circuit 
faulty. 
1. 
Pertorm 
D.C. 
voltage 
check 
of 
generator 
charging 
circuit. 
2. 
Faulty 
battery 
charger. 
2. 
Replace 
charger. 
Generator 
engine 
stops. 
1. 
Fuel 
lift 
pump 
failure. 
1. 
Fuel 
lift 
pump 
should 
make 
a 
distinct 
ticking 
sound. 
Replace 
pump 
with 
spare. 
2. 
Switches 
and/or 
wiring 
loose 
2. 
Inspect 
wiring 
for 
short 
circuits 
and 
loose 
connections. 
or 
disconnected. 
Inspect 
switches 
for 
proper 
operation. 
3. 
Fuel 
starvation. 
3. 
Check 
fuel 
supply, 
fuel 
valves, 
fuel 
lift 
pump. 
4. 
20 
Amp 
circuit 
breaker 
tripping. 
4. 
Check 
for 
high 
DC 
amperage 
draw 
during 
operation. 
Ensure 
breaker 
is 
not 
overly 
sensitive 
to 
heat 
which 
would 
cause 
tripping. 
5. 
Exhaust 
system 
is 
restricted. 
5. 
Check 
for 
blockage, 
collapsed 
hose, 
carbon 
buildup 
at 
exhaust 
elbow. 
6. 
Water 
in 
fuel. 
6. 
Pump 
water 
from 
fuel 
tank(s); 
change 
filters 
and 
bleed 
fuel 
system. 
7. 
Air 
intake 
obstruction. 
7. 
Check 
air 
intake 
filter 
cartridge. 
Engines & GefJerators 