Installation manual

SAFETY
SHUTDOWN
SWITCHES
SAFETY
SHUTDOWN
SWITCHES
The generator is protected by three automatic shutdown
switches. Should shutdown occur,
do not attempt
to
restart
without finding
and
correcting the cause. Refer
to
the
ENGINE
TROUBLESHOOTING
section
of
this manual.
The following is a description
of
these automatic shutdown
switches:
High
Water
Temperature
Switch
A high water temperature switch
is
located on the thermostat
housing. Normally closed, this switch, should the fresh water
coolant's operating temperature reach approximately
210°F
(99°C), will open and interrupt the DC voltage to the fuel
solenoid on the injection pump, thereby shutting off the
engine. This switch resets at
19SOF
(107°C).
Engine
Circuit
Breaker
The generator's engine
is
protected by an engine mounted
I manual reset circuit breaker (20 amps
DC).
Excessive current
! draw or electrical overload anywhere in the instrument panel
wiring
or
engine wiring will cause the breaker to trip.
In
this
event most generators will shut down because the opened
breaker disconnects the fuel supply.
If
this should occur,
; check and repair the source
of
the problem. After repairing
the fault, reset the breaker and restart the generator.
Low
Oil
Pressure
Switch
A low oil pressure shutdown switch is located off the
engine's oil gallery. Normally
open
in
a static state, this
switch's sensor monitors the
engine's
oil pressure. Should
the engine's oil pressure fall to 5-10 psi, this switch will
open interrupting the DC voltage to
the
fuel solenoid on the
injection pump, thereby shutting
off
the engine.
OIL
PRESSURE
SWITCH
LOCATED
AT
THE
FRONT
.
OF
THE
ENGINE
NEXT
TO
THE
CRANKSHAFT
PULLEY
Engines
& Generators
15