Operating instructions

OPERATING
INSTRUCTIONS
REMOTE
PANEL
Starting
the
Generator
To
start the generator, hold the momentary ON switch
in
the
up
(on) position (the green light will come on), then hold the
momentary
START/STOP switch in the up (start) position
(both switches are held up together). After approximately one
second, the starter will engage and the engine will crank (the
green light will dim).
Once the engine is running (the green
light
will brighten», the stalter will disengage, and the
START/STOP switch may then be released to return to its
center
(run mode) position. Continue holding the ON switch
until the engine has sufficient oil pressure, then release it
to
its
center position.
NOTE:
Sfwuld the engine fail to start, release both switches,
wait
20 seconds, and try again. Never
run
the starter more
than
20 seconds
at
a time.
~~
__
OFF/RUN
STOP
OFF
START/STOP
SWITCH
Stopping
the
Generator
11-1.....::_--
OFF/RUN
ON
SWITCH
To
stop the generator, move the momentary START/STOP
switch to the down (stop) position then release
it
to the center
(off/run mode) position. This will de-energize the K2 run
relay
in
the generator's control panel and stop the generator.
Engines
&:
Generators
8
REMOTE
PANEL