Operator`s manual
General 
o 
DESCRIPTION 
OF 
INSTRUMENT 
PANEL 
PREHERT 
4 
w 
START 
~ 
WJ 
STOP 
® 
GENERRTOR 
o 
o 
o 
The manually  operated  series 
of 
Westerbeke  generators 
is 
equipped  with  toggle  switches  and  optioual 
remote panels.  The Standard Instrument Panel (shown above) includes two  gauges which indicate water 
temperatnre in degrees Fahrenheit (WATER 
OF) 
and oil pressure in  pounds per square  inch (OIL PSI). 
This panel is also equipped with two  meters which indicate DC control circuit voltage (VOLTS)  and the 
generator's running time (ELAPSED TIME) in HOURS and 
in 
1/19 hours.  The water temperature and oil 
pressure gauges and the DC volt meter are illuminated; the ELAPSED 
TIME 
meter is not illuminated. 
I. 
PREHEAT:  The PREHEAT switch energizes the engine's glow  plugs,  activates the electric fuel 
pump, bypasses the engine's oil pressure switch, and activates the fuel  run solenoid.  In addition,  this 
switch energizes the START switch. 
2. 
START:  The  START  switch,  when  pressed, energizes  the  starter's  solenoid  which cranks the 
engine.  This switch will  not operate electrically unless the PREHEAT switch 
is 
pressed and  held at 
the same time. 
3. 
STOP:  Through the  STOP  switch  power 
is 
provided to  the fuel  solenoid.  Opening this switch 
deactivates the fuel solenoid and shuts off fuel to the engine, thereby stopping the engine. 
NOTE:  When the engine is manually shut down, the water temperature gauge and oil pressure 
gange will continue to register the last temperature reading and oil pressure reading indicated 
by the gauge before electrical power was  turned 
off. 
The temperature gauge and oil pressure 
gauge will return to zero once electrical power 
is 
restored to these gauges. 