Operator`s manual
Generator Mounting - Location 
The complete generator unit is mounted on lightweight rails by means 
of 
four flexible isolator mounts that 
help prevent the transfer 
of 
vibration from  the generator to  the  rails.  Each generator mounting rail has 
several 
112 
inch bolt holes 
so 
bolts  can be  employed  to properly secure  the  generator  to  its  mounting 
platform. 
The mounting location 
must  be dry, above low-lying vapor areas,  and 
in 
an area where bilge water and 
water from above cannot splash or drip on the generator or drive engine.  The drive engine and generator 
must  be  accessible  for  minor  servicing  and  repairs.  Access  for  major  repairs  should  be given 
consideration as well.  The generator set 
must  be properly ventilated to  provide fresh cooling air for the 
generator end, for  engine combustion needs, and to  remove  heat produced by the engine while operating. 
The generator set  needs  fresh  cool  air in whatever  location  in the vessel it 
is 
installed.  Hot generator 
discharge  air 
!!lli§!.  be removed  from the generator area.  The  platform  on which  the  generator and its 
mounting  rails  are located 
must be strong enough  to support  the  generator  during  all  angles 
of 
vessel 
operation. 
15 
WESTERBEKE GENERATORS 