Operator`s manual
7.6 
KW 
BTD SYSTEM 
SPECIFICATIONS 
FUEL 
SYSTEM 
General 
Fuel 
Injector Pump 
Injectors 
LiftPump 
Air cleaner 
Air Flow (engine combustion) 
COOLING 
SYSTEM 
General 
Operating Temperature 
Fresh Water Pump 
Raw Water Pump 
Raw Water Flow. 
at 
1800 rpm 
(measured before discharging into exhaust 
elbow) 
System Capacity (fresh water) 
LUBRICATION 
SYSTEMS 
General 
Oil Filter 
Sump Capacity (including filter) 
Operating 
Oil Pressure (engine hot) 
Oil Grade 
WESTERBEKE 
GENERATORS 
Open flow - totally self-bleeding 
No.2 
Diesel (cetane #45 or better) 
In-line plunger 
type (Bosch type) 
Throttle type 
12-volt DC; electric 
Plastic Intake 
Silencer 
30.2 cfm (0.85 cmm) 
Fresh water-cooled block, thermostatically-
controlled with heat exchanger. 
170 - 190
0 
F (77 - 88
0 
C) 
Centrifugal type, metal impeller, belt-driven 
Positive displacement, rubber impeller, 
mechanically-driven 
6.5 -
7.0 U.S. gpm (24.6 - 26.5 Ipm) 
4.0 qts (3.79 liters) 
Pressure  type 
by  Trochoid  pump,  gear-driven, 
with external pressure relief valve. 
Full flow, paper element, spin-on type 
3.7 
U.S. qts (3.5 liters) 
35 
-
55 
psi (2.5  3.8 kg/cm
2
) 
API specification 
of 
CC or CD 
10 