Installation manual
SBCG
DESCRIPTION
and
TROUBLESHOOTING
REFER
ALSO
TO
THE
SPECIFICATION
PAGE
BRUSHLESS
CAPACITOR
GENERATOR
Engine
RPM
at 2200
generator turns at
3600 (60Hz) 3000
(50Hz)
60Hz
120
Volts
30.
Ampsfor
SBCG
50Hz
230
Volts
is Amps for
SBCG
TROUBLESHOOTING
CHART
Refer
to
the
following page for
the
BCG Internal
Wiring
Schematic and
the
BCG
Winding
Resistances.
CAUSE
FAULT
No
AC
Output
Voltage
1.
Shorted
Stator.
Residual
Voltage
Line
-
Neutral
at
No
Load
(s-a
VAC)
Low
AC
Output
Voltage
60
-100
Volts
AC
Voltage
Drop
with
Inductive
Load
2.
Open
Stator.
3.
Shorted
Rotor
Diode.
4.
Shorted
Rotor
Thermister.
5.
Shorted
Rotor
Capacitor.
6.
Open
Rotor
Diode.
1.
Faulty
Capacitor.
2.
Open
Exciter
Winding.
3.
Shorted
Exciter
Winding
..
1.
Faulty
Rotor
Diode.
2.
Faulty
Rotor
Winding.
3.
Faulty
Exciter
Capacitor.
1.
Faulty
Rotor
Diode.
2.
Faulty
Exciter
Capacitor.
3.
Amperage
Overload.
NOTE:
It would
be
important
to
inspect
the
pulley and
drive
belt under
the
generator base frame.
RED
ISOLATION
POST
WHITE
N
120V/60Hz
.
BLACK
AC
·CIRCUIT
BREAKER
AC
OUTPUT
CONNECTIONS
DIAGRAM
RED
IS.Q!J\TION
POST
230V/50Hz
Engines & Generators
41