Installation manual

ENGINE
TROUBLESHOOTING/SOFTWARE
DIAGNOSTICS
Engine
CRANK State Shutdowns:
"Engine
CRANK
state is -
DC
circuit breaker on, generator start switch has been pushed
but
engine is
not
up
to
running speed yet. This state only lasts for a few seconds on a typical engine before
the
engine starts
and
transitions
to
the
RUN state.
In
the
CRANK
state, warnings are
not
indicated on
the
LED
display,
and
they are
not
logged.
All
shutdowns are
logged.
Shutdo·wn
Description
Paralnelel's
Possible
cause
No
CAM
speed sensor
o cam sensor adjusted improperly
1
Cam Sensor failure
signal detected by
ECU
-loose
connection
or
corroded wiring
- sensor tip contaminated with
metal
filings
Exceeds 8 second crank
- faulty battery
2
Over-Crank Timeout
duration
o loose connection
or
corroded wiring
o fuel supply insufficient
3
External Alarm
Open circuit
- external alarm fault (i.e. Fireboy)
-loose
connection
or
corroded wiring
o faulty battery
4
Battery Voltage
Low
Less
than
8 volts
-faulty charging circuit
-blown
fuse
o loose connection
or
corroded wiring
No speed signal detected
o loose connection
or
corroded wiring
5
Speed Signal Not Detected
o speed conditioning module faulty
byECU
o sensor
tip
contaminated with
metal
filings
. -
Out
of
fuel
or
fuel
system
not
bled
properly
MAP
reading
out
of
range
- faulty
MAP
sensor
6
MAP
Sensor Fault
o pinched
or
bare
wire
in
harness
«10
kPa
or
>115
kPa)
o loose connection
or
corrbded wiring
Engines & Generators
32