Installation manual

CONTROL
PANEL
START/STOP
PANEL
DESCRIPTION
To
Start:
Press the rocker switch to the start position and
release. (The switch will revert to its center position). The
engine will crank and start electronically. A
green
LED
on the switch will indicate the engine is running.
NOTE:
There
is
a brief delay while
the
ECU self-tests
before
the
start button
responds.
Apply a light load to the generator and allow the engine
to
wann
up to operating temperature before applying heavy
loads.
To
Stop:
Press the rocker switch to stop and release. The
ECU will receive the signal to shut the engine down. The
green LED will go
off
indicating the unit has shut-down.
NOTE:
This
green
LED
may illuminate dimly
when
the
engine
is
not
running.
This
is
part
of
the
self diagnostic circuit and
is
normal.
HOURMETER
7iAI~J.---
LED
DISPLAYS/FAULT
LED'S
START/STOP
~~-1\
1.--1----
ROCKER
SWITCH
GREEN
LED
\..---Joo--f---_
2DA
CIRCUIT
BREAKER
8AFUSE
PN
033769
MAIN
CIRCUIT
BREAKER
SHUTDOWN
(Refer to SAFETY SHUTDOWN SWITCHES)
A shutdown is when the
ECru
(Electronic Control Unit)
stops the generator because it has detected an operating fault
which could cause damage to the engine, the generator, or
create an unsafe operating condition.
FAILURE
TO
START
The start cycle will automatically terminate
if
the engine fails
to start after 8 seconds
of
cranking. Three start attempts can
be performed before an underspeed fault occurs.
This
prevents prolonged cranking
which
can
result
in
the
exhaust filling
with
water
and
backing
into
the
engine.
To try repeat start attempts while solving and repairing the
problem, close the thru-hull (water intake valve). When
the starting problem is corrected do not forget to open the
thru-hull.
~:'
·~f~·
OIL..IIIIJWUIIR!
.
II!XT.
£Un
__
"II"1I1IP
ImIAIUI8T
TRIP
(l01.6mm)
~
...
([ .
911)-
o 0
~----3.34"
(84.84mm)
--~
REMOTE
PANEL
(with
Fault
Display)
A remote panel is available that allows for remote operation
of
the generator. The panel comes with either a 15' or 30'
plug-in extension harness. The start/stop sequence is
identical. Once installed, the engine can be operated by
either panel.
IT.
3.190"
(81.03
mm)
o
o
~
2.60" «66.04mm) --.J
REMOTE
PANEL
(STOP/START
SWITCH
ONLY)
NOTE:
For wiring these
remote
panels,
refer
to
the
Wiring
Diagram section
in
thus
manual.
Engines & Generators