Installation manual
INSTALLATION/EXHAUST
SYSTEM
RAW
WATER
DISCHARGE
The fresh water that flows thru the engine is cooled by a
continuous flow
of
raw water (via the heat exchanger). As
the raw water is discharged overboard, it is used to cool
the exhaust system.
RAW
WATER
SUPPLY
HOSE
(INSTALLING)
The raw water supply hose from the discharge conne.::tion on
the engines cooling system to the inlet connection
of
the
water injected exhaust elbow
must
be
looped a minimum
of
12 inches (30cm) above the vessels loaded water line. ,
On
installations where the water injected exhaust is close to
or
below the vessels loaded water line, provisions must be
made to install a syphon break in the raw water supply hose.
The function
of
the syphon break is to stop the raw water
flow after the engine is shutdown. This flow,
if
not stopped,
will fill the exhaust system and possibly the engine as well.
The raw water supply hose must be looped well above the
loaded water line to allow the syphon break to function
during all attitudes
of
vessel operation to prevent syphoning
when the generator is not operating.
When the generators location is above the loaded water line
of
the vessel during all attitudes
of
vessel operation, it is still
advisable to loop the raw water discharge hose at least 6
•
inches or more above the generator and then down to the
inlet connection on the water injected exhaust elbow.
NOTE:
Always use a quality hose with good wall integrity
or
wire reinforced hose so it will maintain its shape when
looped and also provide proper mechanical support
for
the
hose.
I
I
(
I
:I
EXHAUST
ELBOW
HEAT
EXCHANGER
EXHAUST
BACK
PRESSURE
Measure back pressure after the engine has
reached its normal operating temperature and
with rated amperage output applied to the
generator
(30 amps @60Hz and
15
amps @ 50Hz).
Westerbekes Installation Manual Pub. #43400
has detailed information on back pressure .
I
BACK
PRESSURE
SHOULD
I
NOT
EXCEED
41"
(102.5cm)
I
IN
THE
WATER
COLUMN
OR
EXCEED
1.5
PSI
WHEN
USING
I
A
PSI
GAUGE.
....
~
/"
WATER
COLUMN
MEASURING
EXHAUST
BACK
PRESSURE
Engines & ,Generators
6
POSITION
THE
CLAMP
DVER
THE
TWO
FLANGES
(AND
GASKET)
AND
TIGHTEN
SECURELY