Technical data
Injection Nozzle Adjustment 
Adjust  injection  start  pressure 
by 
increasing 
or 
decreasing  the  thickness  of the  shim washer 
to 
be 
inserted.  Varying shim thickness  by 
0.1 
mm  causes 
injection start pressure 
to 
change 
10 
kg/cm. 
10 
kinds of shims available from 
1.25 
mm 
to 
1.7 mm in 
thickness, 0.05 mm step. 
Injection  start pressure 
Standard 
Allowable limit 
130 
kg/ 
an' 
or 
less 
Injection Nozzle Installation 
Tightening 
torque: 
2.5-3.0kg.m 
Return  pipe 
Assembling  the  Nozzle 
Tightening torque: 
3.5-4.0kg.m 
1. 
Clean  the nozzle holder fitting  surface  of the cylinder head.  Install  the nozzle  holder with  a gasket 
interposed. 
Tightening torque:  5.0 - 6.0 kgm 
2. 
Connect the fuel return pipe and injection pipe. 
Tightening torque: 
Injection pipe 
Fuel 
return pipe 
2.5 -3.5 kgm 
2.5 -3.0 kgm 
61 