Specifications
OPERATING
INSTRUCTIONS
DC
CIRCUIT
BREAKER
ON/OFF
CAUTION:
When
servicing or replacing
DC
components,
tum offtbe
20
amp
DC
circuit
breaker.
fW'/WES1ERBEKE 0 T
'-r--r--r---r-'~
START
STOP
EMERGENCY
STOP
AND
FIREBOY
CONNECTIONS
o
STOP
SWITCH
GENERATOR
CONTROL
PANEL
The
start/stop
rocker
switch
is
the
only
functional
component
on
the
generator
control
panel
used
to
start
and
stop
the
generator.
The
start/stop
rocker
switch
is
a
three
position
switch
with
momentary
contacts in
the
(START)
and
(STOP)
position
and
a
stationary
contact
function
in
the
center (NORMAL).
This
position
allows
the
generator
to
run
once
started
and
also
enables
the
remote
start/stop
panel(s)
to
control the
start/stop
functions
of
the
generator.
The
(START)
position
starts
the
generator and
once
released
reverts
to
the
center
position.
The (STOP) position
stops
the
engine
in
normal
operation
as
well
as
in
an
emergency
situation.
This
position
opens
the
K2
run
relay
which
de-energizes
the engine's
run
circuit
and
shuts
down
the
engine.
Starting
Simply
press
the
(START)
switch
and
the generator
will
start.
A
green
light
will
glow
indicating
the
generator
is
running.
Stopping
Depress
the
(STOP)
side
of the start
switch,
the
green
light
will
go
out
and
the
generator
is
stopped.
Failure
to
Start
The
start
cycle
will
automatically
terminate
if
the
unit
fails
to
start
after
5-6
seconds
of
cranking.
Wait
20
seconds,
then
repeat
the
start.
If
the
unit
again
fails
to
start,
investigate
the
cause.
Sometimes
after
servicing
the
fuel
system
or
changing
the
fuel
filter,
air
can
accumulate
in
the
fuel
line or
the
throttle
body
and
prevent
starting.
The
Schrader
valves
on
the
throttle
body
and
the
fuel
cell
are
used
to
remove
trapped
air.
This
air
is
mixed
with
fuel
and
under
high
pressure.
Follow
the
BLEEDING 11IE FUEL
SYSTEM
instructions
in
this
manual.
-
CHECK
ENGINE
LIGHT
The
check engine light
indicates
a potential emission's
control
issue.
Immediate
action
by
the
operator
should
be
taken
to
troubleshoot
and
correct the emission's related
issue.
REMOTE
START/STOP
PANEL
The
components
on
the
panel
are:
1.
A three
position
start/stop
rocker
switch.
2. A
green
LED
run
indicator light
on
the
rocker
switch.
3. A four
position
LED
fault shut
down
display
board.
The
start/stop
rocker
switch
functions
the
same
as
the
start/stop
rocker
switch
on
the
genemtor's
control
panel
as
previously
explained.
The
green
LED
run
indicator light
on
the
rocker
switch
will
illuminate
when
the
start circuit is
energized.
It
,vill
go
dim
as
the
engine
cranks
and
will
brighten
as
the
engine
starts
indicating
the
generator
is
running.
The
LED
fault
shut
down
display
board
has
four
separate
LED
lights
to
display
to
the
operator
the
cause
of
the
generators
automatic
shut
down.
The
four
LED
displays
are:
low
oil
pressure,
high
engine
operating
temperature,
high
exhaust
temperature
and
engine
over-speedlunder-speed
(flashes).
Should
the
genemtor
shut
down
from
one
of
these
faults,
the
fault
LED
will
remain
illuminated.
To
reset
the
LED,
the
DC
breaker
on
the
control
box must be turned OFF
and
then
back
ON.
This
remote
panel
is
a plub-in accessory
and
is
availab;e
with
a
15'
to
100'
wiring
harness.
Engines & Generators
7