Operator`s manual
Problem
Battery runs down (continued).
Probable Cause
High resistance leak
to
ground.
Low resistance leak.
Alternator.
47
VerificationlRemedy
Check wiring. Insert
sensitive (0-.25 Amp)
meter in battery lines.
(Do not start engine.)
Remove connections and
replace after short is
located.
Check all wires for
temperature rise
to
locate fault.
Disconnect alternator
at output, after a
good battery charging.
If leakage stops, re-
move alternator and
bench test. Repair
or