Operator`s manual
problem
probable Cause
Verification/Remedy
No ignition: cranks,
Faulty fueling system.
1.
Check
for
fuel
but does
not
start;
to
generator engine.
fuel solenoid energized.
2. Check
for
air in
fuel system. Allow
system
to
self-bleed.
3. Fuel lift
pump
faulty.
4.
Filters clogged.
(Replace filters
and allow system
to
self-bleed
by
de-
pressing only the
PREHEAT switch.)
Failure
to
stop.
Fuel solenoid
Stop engine
by
man-
return spring.
ually moving the
throttle lever
to
shut
off. That failing,
shut off fuel and air.
Check fuel solenoid
linkage and repair
for
free movement.
STOP switch failure. Stop engine
by
depres-
sing emergency STOP
switch on engine
or
manually moving throt-
tle
to
shut off. Test
switch with ohmmeter.
Fuel injection pump
Depress emergency
failure. STOP switch on engine.
Stop engine
by
opening
the high pressure in-
jector lines
at
the
injectors and stop air
intake.
Engine stops. Low oil pressure
or
Check oil level; check
overheated.
fresh and sea water
cooling.
Low oil pressure
Check
for
satisfactory
switch opens. operation with switch
bypassed. Check with
ohmmeter.
45