Operator`s manual
4-Pole Generator Voltage
Load
Speed
Frequency 120V(110) 240V (220)
Applied
(rpm) (Hertz) Plants Plants
None 1830 62 122 244
(1530)
(52)
(112) (224)
Half
1800
60
120 240
(1500) (50) (110)
(220)
Full 1755
59
110 220
(1455)
(49)
(100) (200)
The output voltage should be checked periodically
to
ensure proper operation of the generating plant and
the appliances it supplies.
If an AC voltmeter
or
ampmeter is not installed
to
monitor voltage and load, check it with a portable meter
and amp-probe.
Preventive
Maintenance
(Generator)
Maintenance on the generator is minimal.
1.
Keep the generator clean,
dry
and well-ventilated.
2.
Ensure that all connections are clean and tight and that cables carrying AC voltage are properly supported
and protected against chafing.
3.
The rear armature bearing is lubricated and sealed; therefore,
no
maintenance is required. If the bearing
becomes rough
or
noisy, replace it.
Generator
Troubleshooting
A complete and illustrated text on troubleshooting the
BTD
series
of
generators is furnished in the Technical
Manual which is available through
your
local dealer.
40