Installation Instructions
Installation and Operator Handbook Installation Instructions
AMX–MA–00653 Issue 0.03 (USA) 5
Unpack the DRB-25 as follows:
• Carefully remove the DRB-25 cabinet from its packaging and relocate to a convenient level work
surface.
• Remove all protective wrapping and inspect the cabinet for signs of damage or loose parts. Notify the
supplier or its agent immediately if any is noted.
• Remove each of the modules in turn from their packages, unwrap and inspect as for the cabinet.
Notify the supplier or its agent immediately if any damage or loose parts are noted.
3.5 INSTALLATION
Take care to align each module correctly into its guide rails. Ensure
that the module is correctly mated into the backplane of the DRB-25
and the connectors are firmly seated. Failure to do so may result in
damage to the module or DRB-25 system.
3.5.1 Tools Required
The following tools should be on hand during installation:
• Flat-bladed screwdrivers (small, medium and large).
• Cross-recessed (Phillips) screwdriver (large and medium).
• Cable ties and cutters.
• 9/32 inch (7 mm) hexagonal nut driver.
• Multimeter with pointed probes for continuity and DC voltage measurements.
3.5.2 Installing the DRB-25 Cabinet
If the DRB-25 is to be desk mounted then screw the supplied feet to the four threaded inserts on the underside
of the case and position the case as required.
If the cabinet is to be rack-mounted then assemble the rack mounting brackets and case as shown in Figure 3-
1: DRB-25 Rack Mounting Arrangement :
1. Fit the brackets to the rack using the caged nuts and bolt supplied.
2. Slide the DRB-25 case into the brackets.
3. Fix the DRB-25 in place by locating the two studs at the rear of the case through the hole in each
bracket, and secure using the nuts supplied.
4. Set the DRB-25’s Identity (Box ID) and fit the modules as described in the following sections.