User Manual

Installation and Operator Handbook Programming and Configuration
AMX-MA-00657 Issue: 1.02 (USA) Page 19
Figure 5-9 Tone Remote Properties
F1 may be allocated to Increase Audio and Change Channel. F2 may be allocated to Decrease Audio and
Change Channel. F3 F12 may only be allocated to Change Channel functions. The DMR Tone Remote
functions are pre-programmed to detect the following industry standard tones. The function tone
frequencies are listed in Table 5-5.
Table 5-5 Function Tone Frequencies
Function Frequency (Hz) Level (dBm) Function Frequency (Hz) Level (dBm)
F1 1950 0 F2 1850 0
F3 1750 0 F4 1650 0
F5 1550 0 F6 1450 0
F7 1350 0 F8 1250 0
F9 1150 0 F10 1050 0
F11 950 0 F12 850 0