Figure 5-9 Tone Remote Properties
F1 may be allocated to Increase Audio and Change Channel. F2 may be allocated to Decrease Audio and
Change Channel. F3 – F12 may only be allocated to Change Channel functions. The DMR Tone Remote
functions are pre-programmed to detect the following industry standard tones. The function tone
frequencies are listed in Table 5-5.
Table 5-5 Function Tone Frequencies
Function Frequency (Hz) Level (dBm) Function Frequency (Hz) Level (dBm)
F1 1950 0 F2 1850 0
F3 1750 0 F4 1650 0
F5 1550 0 F6 1450 0
F7 1350 0 F8 1250 0
F9 1150 0 F10 1050 0
F11 950 0 F12 850 0