7.3 Programmer description
7.3.1 General
A survey of the most important features:
w
Programs: 8 or 16 (dependent of order)
w
Control outputs: 4
w
Segments: 16 per program
w
Segment types: ramp (set-point and time)
ramp (set-point and gradient)
hold segment (holding time)
step segment (with alarm suppression)
end segment
All segment types can be combined with ”Wait at the end and call operator”
w
Time unit: configurable in hours:minutes or
minutes:seconds
w
Maximum segment duration: 9999 hours = 1 year 51 days
w
Maximum program duration: 16 x 9999 hours=>18years
w
Gradient: 0,01°C/h ( /min) to 9999°C/h ( /min)
w
Program name: 8 characters, adjustable via
8800/8840 Configurator software
w
Bandwidth control: bandwidth high and low (b.Lo,b.Hi)
limits defininable for each program
Programmer level
Programmer description 68 8840 profiler
b.Hi
b.Lo
hold segment
step segment
analog track
control track 1
control track 2
control track 3
control track 4
1
24
5
12
13
14
15
16 (8)
16
PRESET
END
PRESET
RESET
START ENDprogram time run off
3
program end