4 Configuration parameters
4.2.10Configuration - Interfaces
Parameter Value/Selection Description
Serial interface
Interface type Configuration
Interfaces
RS232/RS485
Interface type
RS232,
RS485
Parameters for the serial
interface (extra code)
Protocol Configuration
Interfaces
RS232/RS485
Protocol
MODbus,
Jbus
Baud rate Configuration
Interfaces
RS232/RS485
Baud rate
9600 bps,
19200 bps,
38400 bps
Data format Configuration
Interfaces
RS232/RS485
Data format
8-1-none,
8-1-odd,
8-1-even,
8-2-none
Device address Configuration
Interfaces
RS232/RS485
Device address
1 —254
Min. response time Configuration
Interfaces
RS232/RS485
Min. response time
0 —500ms
Ethernet interface
IP address Configuration
Interfaces
Ethernet
IP address
000.000.000.000 …
192.168.000.010
255.255.255.255
The IP address for the
recorder is set here.
Subnet mask Configuration
Interfaces
Ethernet
Subnet mask
000.000.000.000 …
255.255.000.000
255.255.255.255
The subnet mask is set
here.
Devices are combined into
subnets through the sub-
net mask. All devices
whose IP address, when
AND-linked, is identical to
the subnet mask, belong to
one subnet and can thus
communicate with each
other.
Gateway Configuration
Interfaces
Ethernet
Gateway
000.000.000.000
255.255.255.255
The address for the
standard gateway is set
here. Devices that do not
belong to a subnet can
communicate through the
standard gateway.