Instruction Manual

69
4 Configuration parameters
Ext. Ctrl signal Configuration
Counter/integrator
Ext. ctrl signal
Bin. inp. 1 — 4,
Logic channel 1 — 6,
Low alarm 1 — 6,
Low comb.al.,
High alarm 1 — 6,
High comb.al.,
Count/Int/Al 1 — 6,
C/i. comb.al.,
Comb. alarm,
CF inserted,
IntMemAlmCF,
IntMemAlmSer,
MemAlmCFcard,
Error, Modbus flag,
Only programmable, if the
parameter Type is set to
“external” on at least one
counter/integrator.
Summation of the counter/
integrator values will only
take place if the selected
digital signal is set to “1”.
When changing to “0”, the
values will be saved and
reset.
Weekday Configuration
Counter/integrator
Weekday
Monday,
Tuesday,
Wednesday,
Thursday,
Friday,
Saturday,
Sunday
Only programmable, if the
parameter Type is set to
“Weekly” on at least one
counter/integrator.
The counter/integrator
values are saved on the
selected day on reaching
the synchronizing time.
Daily start time Configuration
Counter/integrator
Daily start time
any time
(06:00:00)
Only programmable, if the
parameter Type is set to
“Daily from-to” on at least
one counter/integrator.
Daily end time Configuration
Counter/integrator
Daily end time
any time
(18:00:00)
Only programmable, if the
parameter Type is set to
“Daily from-to” on at least
one counter/integrator.
Generate reset Configuration
Counter/integrator
Generate reset
Off,
Bin. inp. 1 — 4,
Logic channel 1 — 6,
Low alarm 1 — 6,
Low com.al.,
High alarm 1 — 6,
High comb.al.,
Count/Int/Al 1 — 6,
C/i. comb.al.,
Comb. alarm,
CF inserted,
IntMemAlmCF,
IntMemAlmSer,
MemAlmCFcard,
Error, Modbus flag,
Here you can determine
the event which will reset
all counter and integrator
counts (without saving).
v Page 19
“External reset”
Parameter Value/Selection Description