4.2.3 Configuration - Analog inputs
Enable options Configuration
➔ Device data
➔ Enable options
This parameter is used to
enable additional
functions, e.g. the math/
logic module and counter/
integrator. The parameter
will not be available if all
the recorder functions have
been enabled.
Enable options:
Computed code
No.
Configuration
➔ Device data
➔ Enable options
➔ Computed
code No.
(display a code No.) The value that is shown
here must be passed on to
the manufacturer. The
manufacturer will then
send you the release code.
Enable options:
Authorization code
Configuration
➔ Device data
➔ Enable options
➔ Authorization
code
Authorization code
entry
Enter the authorization
code (release code) you
received here.
Device-info text In the setup program, the parameter Configuration level Device data can be used
to enter a device-Info text (max. 500 characters). The text is saved together with the
measurement data, and can be displayed in the PCA3000 evaluation software. The
text will not be shown on the instrument.
Parameter Value/Selection Description
Sensor Configuration
➔ Analog inputs
➔ Analog input 1—6
➔ Sensor
Off,
RTD,
Thermocouple,
Current,
Voltage
Depending on the sensor
that was selected, only the
relevant parameters can be
selected when configuring
the analog input.
Linearization Configuration
➔ Analog inputs
➔ Analog input 1—6
➔ Linearization
Linear, Pt100, Pt100 JIS,
Pt100 GOST, Pt500,
Pt1000, Pt50, Ni100,
Cu50, Cu100, Fe-Con J,
NiCr-Con E, NiCr-Ni K,
NiCrSi N, Cu-Con T,
PtRh-PtRh B,
PtRh-Pt R, PtRh-Pt S,
Cu-Con U, Fe-Con L,
W3W25Re D,
W5W26Re C,
ChromelCopel
Connection circuit Configuration
➔ Analog inputs
➔ Analog input 1—6
➔ Connection circuit
2 — 4 wire Only for sensor type:
resistance thermometer
Cold junction Configuration
➔ Analog inputs
➔ Analog input 1—6
➔ Cold junction
Intern.Pt100
Extern. const
Parameter Value/Selection Description