Instruction Manual

4 Configuration parameters
62
4.2.2 Configuration - Instrument (device) data
Parameter Value/Selection Description
Device name Configuration
Device data
Device name
16 characters
Date Configuration
Device data
Date and time
Date
any date Entry of the current
date
Time Configuration
Device data
Date and time
Time
any time Entry of the current
time
Time
synchronization
Configuration
Device data
Date and time
Time
synchroniz.
Off,
Bin. inp. 1 — 4,
Logic channel 1 — 6,
Low alarm 1 — 6,
Low comb.al.,
High alarm 1 — 6,
High comb.al.,
Count/Int/Al 1 — 6,
C/i. comb.al.,
Comb. alarm,
CF inserted,
IntMemAlmCF,
IntMemAlmSer,
MemAlmCFcard,
Error, Modbus flag,
With the help of this
parameter (function), the
system clocks of several
paperless recoders can be
simultaneously
synchronized.
When a binary input has
been selected and is
activated (transition from
“Low” to “High”), then the
time can be synchronized.
The seconds are decisive
in the time change. They
are used for rounding the
time up or down.
Example:
12:55:29 -> 12:55:00
12:55:30 -> 12:56:00
Summer time
(switch)
Configuration
Device data
Summer time
Switch
Off,
User timed,
Automatic
Automatic:
2:00 hrs or 3:00 hrs on the
last Sunday in March or
October
Summer time
(start date)
Configuration
Device data
Summer time
Start date
any date Can only be set if
switch is set
to user timed
Summer time
(start time)
Configuration
Device data
Summer time
Start time
any time Can only be set if
switch is set
to user timed
Summer time
(end date)
Configuration
Device data
Summer time
End date
any date Can only be set if
switch is set
to user timed
Summer time
(end time)
Configuration
Device data
Summer time
End time
any time Can only be set if
switch is set
to user timed