Datasheet
IP54
+50°C
-20°C
NTERFACENTERFACE
75
www.werma.com
Cable not included in assembly
TECHNICAL DIAGRAMS:
see page 292
Signal Towers
●
modular
KombiSIGN 50
Zulassungs-Nr. 2001
TECHNICAL SPECIFICATIONS:
ORDER SPECIFICATIONS AS-INTERFACE-ELEMENT KOMBISIGN 50:
AS-Interface Element for KombiSIGN 50845
AS-Interface Element with additional
external voltage
Number of signal elements max. 4
Type of signal elements Permanent light elements
LED elements
Buzzer elements
IO-Code 8
ID-Code F
Power supply via bus conduction
Operating voltage 25 V … 31.6 V
Current consumption Imax 50 mA
Polarity reversal protection integrated
Watchdog integrated
Outputs 4, relays
On-load voltage additional external voltage:
10 V…30 V
10 V…230 V
Current carrying cap.
ΣΣ
Imax 1.5 A
Short circuit/overload pro. fuse M 1.6 A
DC
A
C
A
C/DC
DC
AC
AC/DC
AS-Interface-Element 845 800 68
with add. external voltage
The Kombi
SIGN
50 Signal Tower with AS-Interface
Element is capable of total communication: Through
s
imple integration of an AS-Interface Element the
actuators are connected to the networking system
Actuator-Sensor-Interface – this considerably reduces complex wiring.
This element is mounted as the first tier of the individual signal tower