CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Range
[Factory Setting]
Parameter
Unit
Description / Notes
P000
0 to 999
Parameter
[ 0 ]
Access
1
6.3.1
Access and Read-only Parameters - P000 to P099
P002
0 to 6553
Frequency
[ - ]
Proportional
0.01 (
99.99);
Value
0.1 (
100.0);
1 (
1000)
P003
0 to 1.5 x I
nom
Motor Output
[ - ]
Current
0.01 A (
9.99 A);
0.1 A (
10.0 A)
P004
0 to 862
DC Link Voltage
[ - ]
1
V
Releases the access to change the parameter values.
The password is 5.
The use of the password is always active.
Indicates the value of P208 x P005.
When the vectorcontrol mode is used (P202= 2), P002
indicates the actual motor speed in rpm.
In case of different scales and units, use P208.
Indicates the inverter output currentinAmps (A).
Indicates the actual DC link voltage, in volts (V).
P005
0
.00
to
300
.0
Motor
Output
[ - ]
Frequency
0.01 Hz
(
99.99 Hz);
0.1 Hz (
100.0 Hz)
Indicates the inverter output frequency in Hertz (Hz).
P007
0 to 600
Motor Output
[ - ]
Voltage
1 V
Indicates the inverter output rms voltage, in volts (V).
Following notes may appear in some parameters during the
detailed description:
(1)
This parameter is onlydisplayed in vectormode(P202 = 2).
(2)
This parameter is only displayed in
scalar mode P202 = 0
or 1.
(3)
This parameter can be changed only when the inverter is
disabled (stopped motor).
(4)
This parameter is only available with HMI-CFW08-RS.
(5)
The analog input value is represented by zero when it is
notconnected toanexternalsignal.Inordertouseananalog
input as a digital input with NPN logic (P235 or P239 = 3),
it is necessary to connect a 10 k
resistor from terminal 7
to 6 (AI1) or 8 (AI2) of the control terminal strip.
(6)
This parameter is only available in the CFW-08 Plus
version.
(7)
The parametervaluechangesautomaticallywhen P203 =1.