User`s guide
70
CHAPTER 4 - KEYPAD (HMI) OPERATION
Inverteris Ready to be started.
Line voltage is too low for inverter
operation (undervoltage condition).
Inver
ter is in a fault condition. Fault code
is flashing on the display. In the example
there is the fault code E02 (refer to
chapter 7).
Inverter is applying a DC current on the
motor (DC braking)
according to the
values programmed at P300, P301 and
P302 (refer to chapter 6).
Inverter is running self-tuning routine to
identify motor parameters automatically.
This operation is controlled by P408
(refer to chapter 6).
COPYfunction (availableonlyattheHMI–
CFW08-RS), it copies the inverter
programminginto the HMI.
COPYfunction (availableonlyattheHMI–
CFW08-RS), it copies the programming
from the HMI into the inverter.
Inverter in the Sleep rdy mode.
NOTE!
The display also flashes in the following conditions, besides
the fault conditions:
Trying to change a parameter value when it is not allowed.
Inverter in overload condition (refer to chapter 7).
4.2.2
InverterStatus
ParameterP121 storesthe speed
(frequency)
referenceset by
the keys:
When pressed, it increases the speed (frequency)reference.
Whenpressed, it decreases the speed (frequency) reference.
Reference Backup:
The last frequency reference set by the keys and
is
stored when inverter is stopped or theAC power is removed,
provided P120 = 1 (reference backup active is the
factory
default).Tochange thefrequencyreference before starting the
inverter, thevalue ofthe parameter P121 mustbe changed.