User`s guide

184
CHAPTER 8 - CFW-08 OPTIONS AND ACCESSORIES
Inverter enabling (provided P229 = 2 for LOC or P230 = 2 for REM).
8.24.5.2
Message Examples
with Basic Variables
CHSL0: 1 - serial local reference
CHSL1: 1 - serial local forward/reverse selection
CHSL2: 1 - serial local On/Off selection
CHSL3: 1 - serial local JOG
CHSL4: 1 - serial remote reference
CHSL5: 1 - serial remote forward/reverse selection
CHSL6: 1 - serial remote On/Off selection
CHSL7: 1 - serial remote JOG selection
CHSH0: 1 - serial local/remote selection.
Changing inverter from forwardto reverse (provided P229 = 2 forLOC or P230 = 2
for REM) - if P231 = 2.
1) Master:
C. L. Code
general enabling = 1
ramp enabling = 1
addr. 7
2)Inverter:
G
ACK
3) Master:
EOT
EOT
G
STX
0
0
7
0
3
=
0H
3H
0H
3H
ETX
BCC
1) Master:
C. L. Code
Reverse = 0
addr. 7
EOT
G
STX
0
0
7
0
3
=
0H
4H
0H
0H
ETX
BCC
2)Inverter:
G
ACK
3) Master:
EOT
JOG enabling
(
provided
P22
9
=
2
for
LOC o
r
P2
30
=
2
for
REM)
.