User`s guide
182
CHAPTER 8 - CFW-08 OPTIONS AND ACCESSORIES
EL8:
0 = ramp enabling (start/stop) inactive
1 = ramp enabling active
EL9:
0 = general enabling inactive
1 = general enabling active
EL10:
0 = reverse
1 = forward
EL11:
0 = JOG inactive
1 = JOG active
EL12
0 = local
1 = remote
EL13:
0 = without undervoltage
1 = with undervoltage
EL14 :
not used
EL15:
0 = without error
1 = with error
Inverter
enabled
EL8 =
EL9 = 1
}
Error code:
hexadecimal error number
Ex.:
E00 00H
E01 01H
E10 0AH
V03 (code 00703)
Selection of the logical control:
Writing variable, whose bits have the following meaning:
BYTE HIGH:
desired action mask. It order to enable the
action, the corresponding bit should be set to 1.
CL8: 1 = enabling ramp (start/stop)
CL9: 1 = general enabling
CL10: 1 = forward/reverse rotation
CL11: 1 = JOG
CL12: 1 = local/remote
CL13: not used
CL14: not used
CL15: 1 = inverter “RESET”
Where:
Logical status:
EL15
EL14
EL13
EL12
EL11
EL10
EL9
EL8
CL15
CL14
CL13
CL12
CL11
CL10
CL9
CL8
MSB
LSB