User`s guide

175
CHAPTER 8 - CFW-08 OPTIONS AND ACCESSORIES
ADDRESS
(P308)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
ASCII
CHAR
DEC
HEX
@
64
40
A
65
41
B
66
42
C
67
43
D
68
44
E
69
45
F
70
46
G
71
47
H
72
48
I
73
49
J
74
4A
K
75
4B
L
76
4C
M
77
4D
N
78
4E
O
79
4F
P
80
50
Q
81
51
R
82
52
S
83
53
T
84
54
U
85
55
V
86
56
W
87
57
X
88
58
Y
89
59
Z
90
5A
]
91
5B
\
92
5C
[
93
5D
^
94
5E
_
95
5F
This interface permits the linkage of up to 30 inverters to a
master (PC, PLC, etc.), attributing and setting for each inver-
ter an address (1 to 30). In addition to these 30 addresses,
there are two addresses to perform special tasks:
Address 0:
any inverter in the network is inquired,
independently of its address. Only one inverter can be
connected to the network (pointto point) in order toprevent
short-circuits in the line interface.
Address 31:
a control can be transmitted to all inverters in
thenetworksimultaneously
, withoutacceptance recognition.
List of addresses and correspondingASCII characters:
8.24.2.1
RS-485
Table 8.6
- Adresses and corresponding ASCII characters list