User`s guide
160
CHAPTER 8 - CFW-08 OPTIONS AND ACCESSORIES
The following figure shows some possibilities for connecting
the module in a CANopen network. Usually, the connection a)
is applied, but connection b) can also be used according to
the situation. Notice that terminal indicated by the symbol
shall be connected to the ground.
Figure 8.20 a) and b) -
Connection possibilities for the KFB-CO-CFW08 module
ATTENTION!
This module can onlybe used with the drives that have the
“A3” initials in the nameplate (refer to item 2.4 of this ma-
nual). Otherwise, the CANopen communication as well as
the keypad will not work.
Itis notpossible to use theparallelkeypad, the serialremote
keypad, theparallel remotekeypad,and the serial protocols
(such as ModbusandWEG)with version“A3” of the control
board.
DeviceNet Communication Module and Keypad:
This optional module, with a DeviceNet interface (plug-in
connector) and a keypad,is installed in thefrontof the inverter
in the place of the standard parallel keypad (HMI-CFW08-P).
For instruction on how inserting and removing this module,
refer to the installation instruction for the KCS-CFW08 in this
manual.
The functions of each pin are indicated in the silk screening
above the communication connector.
It is possible to command, setup and monitor the CFW-08
through this communication interface.In thiscase, the master
can be a PLCorother device thatsupports thiscommunication
protocol.
This module can be purchased along with the inverter just by
includingthe code “A4” in the control board fieldof the product
part number, such as, CFW080040S2024PO
A4
Z (refer to
item 2.4 of this manual for further informationon howordering
the product).
8.15
KFB-DN-CFW08
CFW-08
CAN_H
CAN_L
CAN_H
CAN_L
Shield
Shield
V-
V-
XC13
Master
CFW-08
CAN_H
CAN_L
CAN_H
CAN_L
Shield
Shield
V-
V-
XC13
Master
b)
a)