User`s guide

153
CHAPTER 8 - CFW-08 OPTIONS AND ACCESSORIES
8.7
MIS-CFW08-RS
Serial i
nterface
used exclusively for
HMI-CFW08-RS
keypad
connection to inverter.
The procedures for insertion and removing of the MIS-
CFW08-RS are similar to those shown in
f
igure 8.1
6
for the
KCS-CFW08 module.
Figure 8.10
- Dimensions in mm [in] of the MIS-CFW08-RS serial
communication module for the external serial HMI
Cables used to connect the inverter to the external serial
interfacekeypad (HMI-CFW08-RS).There are6 cable options
ranging in lengths from1 m to10 m (3.28 ft to 32.8 ft). The user
mustselectamong theselengths according to the requirement.
The cable CAB-RS must be laid separately from the power
wiring by meeting the requirements for the control wiring(refer
to item 3.2.5).
8.8
CAB-RS-1
CAB-RS-2
CAB-RS-3
CAB-RS-5
CAB-RS-7.5
CAB-RS-10
NOTE!
Cables with 5 m (16.4 ft) and longer ones (5 m (16.4 ft), 7.5 m
(24.6ft) and 10 m (32.8 ft)) are shielded, andtheir shield must
be connected to the ground.
Figure 8.11
- CAB-RS-X
Inverter
RJ Connector
Keypad
DB9
Connector
8.6.3
Keypad Copy Function
The HMI-CFW08-RS keypad still has an additional function:
thekeypadcopyfunction.This functionisuseful whenone wants
tocopythe settings of one inverter (sourceinverter) to another
(target inverter) or one needs to program several inverters
with the same settings.
Thisis done as follows: the parameters of the source inverter
are copied to a non-volatile memory of the HMI-CFW08-RS
keypad , andthen from this keypad to another inverter (“target
inverter"). The keypad copy function is controlled by the
parameter P215.
For further information onthis function referto parameter P215
in the chapter 6.
57
[2.24]
43
[1.69]
21
[0.83]
20
[0.79]