User`s guide
118
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Time
Output
Frequency
(Motor Speed)
0 V
Open
DI - Start/Stop
Minimum
Frequency
(P133)
Reset
DI4 - Decrease
DI3 - Increase
Open
Time
Time
Time
0 V
0 V
e) ELECTRONIC POTENTIOMETER (EP)
Open
Open
0 V
Time
Time
Output
Frequency
(Motor
Speed)
DI - FWD/
REV
CW
CCW
f) FWD/REV
Open
Open
0 V
Time
0 V
Time
P102
P100
DI - Start/Stop
DI - Ramp 2
g) RAMP 2
P103
P101
Time
Figure 6.21 (cont.) e) to h)
- Time diagrams of the digital input functions
Time
Output
Frequency
(Motor
Speed)
0 V
0 V
Start/Stop
JOG Frequency
(P122)
Deceleration
Ramp
0 V
DI - JOG
General
Enabling
Open
Open
Open
Acceleration
Ramp
h) JOG
Time
Time
Time
Output
Frequency
(Motor Speed)