User`s guide
115
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Check possible options in the table below and details
about the operation of the functions in the figure 6.21.
Function description:
Not used or general enable:
P263 = 0
When the command source is the terminals, i. e., if
P229 = 1
for the local mode or P230 = 1 for the remote
mode, the digital input DI1 operates as general enable.
Otherwise, no function is attributed to the input DI1
Not used or start/stop:
P265,P266, P267orP268 = 8.
If the inverter is operating in local mode and P229 = 1,
the digital input DI3/DI4/DI5/DI6 operates as start/stop.
If the inverter is operating in remote mode and P230 = 1,
the digital input DI3/DI4/DI5/DI6 operates as start/stop.
Otherwise no function is associated to the inputs DI3/
DI4/DI5/DI6.
Multispeed:
P264, P265, P266 or P267 = 7.
You must program P221 and/or P222 = 6.
Multispeed with ramp 2
and
FWD/REV with ramp 2:
If different acceleration and deceleration times are
desired for a determined operation condition (for
instance, for a frequencysetor for a direction of rotation),
please check if it is possible to use the multispeed
functions with ramp 2 and the FWD/REV with ramp 2.
Accelerates EP
and
Decelerates EP
(EP – Electronic
Potentiometer): P265 = P266 = 5 or P267 = P268 = 5.
You must program P221 and/or P222 = 4.
Local/Remote
Open/0 V at the respective digital input.
Disable Flying Start:
Refer tothe comments in the parametersP310and P311.
Manual/Automatic:
Details about thisfunction can be found in the item 6.3.5
Special Function Parameters.
Range
[Factory Setting]
Parameter
Unit
Description / Notes
P263
(3)
0 to 14
Digital InputDI1
[ 0
]
Function
-
P264
(3)
0 to 14
Digital InputDI2
[ 0
]
Function
-
P265
(3) (7)
0 to 16
Digital InputDI3
[ 10
]
Function
-
P266
(3)
0 to 16
Digital InputDI4
[ 8 ]
Function
-
P267
(3) (5)
0 to 16
Function of the
[11 ]
Digital InputDI5
-
P268
(3) (5) (6)
0 to 16
Function of the
[11 ]
Digital InputDI6
-