Replacement Part List
MAINTENANCE
DRAINING THE FUEL TANK
Drain and clean the fuel tank each year, or before storing the generator for longer than two months. 
To drain the fuel tank and carburetor: 
1. Using a Phillips-head screwdriver, remove the service panel 
on the opposite side of the recoil starter by unscrewing the 
top two screws.
2. Locate the carburetor and the transparent drain tube that 
extends down through the base plate of the generator (Fig. 
38).
3. Prepare an approved gasoline-storage container and direct 
the end of the transparent tube into the container. 
4. Remove the fuel cap. Turn the 2-in-1 dial switch to the 
“RUN” position (Fig. 39). This will open up the fuel valve. 
5. Open up the carburetor drain screw (Fig. 38) with a Phillips  
screwdriver. Fuel will start draining from the carburetor and 
fuel tank through the drain tube. 
NOTE: The draining process may take a few hours, depending 
on the amount of fuel in your gas tank.
6. Once fuel is completely drained from the tube, reinstall the 
fuel cap and turn the 2-in-1 switch to “OFF” position. Tighten 
the drain screw with the screwdriver and reinstall the service 
panel.
7. Start and run the generator until the fuel runs out.
8. Store the emptied gasoline in a suitable place. DO NOT 
store flammable materials near the gasoline. 
CAUTION: Store the emptied gasoline in a suitable place. Never store fuel for more than 2 months.
Fig. 38 
Fig. 39 
Drain TubeDrain TubeDrain Tube
CarburetorCarburetor
Drain ScrewDrain Screw
Carburetor
Drain Screw
38