Product Manual
19
STORAGE & TRANSPORT PROCEDURES
CAUTION: Never place any type of storage cover on the generator while it is still hot.
If the generator is being stored for short periods of time (30 to 60 days), add stabilized fuel to the fuel tank until
full. NOTE: Filling the tank reduces the amount of air in the tank and helps fight deterioration of fuel. Run the
engine for 2 – 3 minutes allowing stabilized fuel mixture to circulate through the carburetor. When storing the
generator for extended periods of time:
• Drain the fuel tank (see “Draining the Fuel Tank” in the “Maintenance” section).
• Change oil.
• Do not obstruct any ventilation openings.
• Keep the generator in a cool dry area.
When transporting generator:
• Drain the fuel tank if possible (see “Draining the Fuel Tank” in the “Maintenance” section).
• Keep the generator upright. Never place the generator side down. Doing so will make it difficult to start.
SPECIFICATIONS
DC output
Rated Voltage 12 VDC
Rated Amperage 8.3 A
Rated Wattage 100 W
USB Charger 5V, 1 A & 2.1 A
AC output
Rated Wattage 2800 Watts
Surge Wattage 3100 Watts
Rated Voltage 120 V
Rated Amperage 23.3 A
Frequency 60 Hz
Phase Single
Dimensions 26.75 x 20 x 23 inches
Weight 81.4 lbs
Engine
Engine type 4 stroke, OHV, single cylinder with forced air cooling system
Spark plug gap 0.6 - 0.7 mm (0.024 - 0.028 in)
Spark plug torque 1/2 - 3/4 turn after gasket contacts base or 15 ft.lb
Displacement 212 cc
Fuel tank capacity 1.85 gallons 87 octane minimum
Oil capacity 0.58 quarts (0.55 liters)
Lubrication system Splash lubrication
Run time on 50% load 7.5 hours
Noise rating (from 22 ft. with
ambient rating of 44 dB)
57 dB (no load) 58 dB (1/4 load)
60 dB (1/2 load) 63 dB (3/4 load)
Spark plug A5RTC