Product Manual

11
STARTING THE ENGINE
To start the generator, perform the following steps:
1. Unplug all electrical devices from the generator during ignition. Otherwise it will be difficult for the engine to
start.
2. To maximize safety, make sure the generator is properly grounded (Refer to “Ground the Generator”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “ON” position (See Figure 4).
5. Move the choke lever to the “CLOSE” position (See Figure 5).
6. Set the ON/OFF Switch to the “ON” position.
7. Pull on the recoil starter handle slowly until a slight resistance is felt, then pull quickly to start the engine. Re-
turn cord gently into the recoil starter. Never allow the cord to snap back.
8. If engine fails to start, repeat step 7. NOTE: After repeated failed attempts to start the engine, please consult
the troubleshooting guide before attempting again. If problems persist please call (800) 232-1195 M-F 8-5 CST.
9. Once the engine has started, slowly return the choke lever all the way to the “OPEN” position.
10. Allow the engine to run for several minutes before attempting to connect any electrical devices. This allows
the generator to stabilize its speed and temperature.
Allow the generator to run for several minutes before attempting to connect any electrical devices. This allows
the generator to stabilize its speed and temperature.
STARTING THE GENERATOR
Fig. 4 - Fuel Valve Fig. 5 Choke Lever