SDS

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS170412016AS 001
Safety Data Sheet
Page 6 of 14
Do not allow product to reach sewage system or any water source.
Inform respective authorities in case of seepage into water course or sewage system.
Do not allow to enter sewers/ surface or ground water.
Methods and material for containment and cleaning up:
If battery casing is dismantled, small amounts of electrolyte may leak. Collect all released material in a plastic
lined container. Dispose off according to the local law and rules. Avoid leached substances to get into the earth,
canalization or waters.
Section 7- Handling and Storage
Precautions for safe handling
Handling In case of rupture: Handle in accordance with good industrial hygiene and safety practice. Avoid
contact with skin, eyes or clothing. Use personal protection equipment.
Conditions for safe storage, including any incompatibilities
Storage Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up.Keep out of the
reach of children.
Incompatible Products
Strong acids. Strong oxidizing agents. Strong bases.
Section 8- Exposure Controls, Personal Protection
(a)Control parameters
Exposure Guidelines
Chemical name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt Oxide
(CoLiO2)
TWA: 0.02 mg/m
3
-
Graphi
te
7782-42
-5
TWA: 2 mg/m
3
respirable
fraction all forms
except
graphite fibers
TWA: 15 mg/m
3
total
dust synthetic
TWA: 5 mg/m
3
respirable
fraction synthetic
(vacated) TWA: 2.5
mg/m
3
respirable dust
natural
(vacated) TWA: 10 mg/m
3
total
dust
synthetic
(vacated) TWA: 5
mg/m
3
respirable fraction
synthetic
TWA: 15 mppcf
IDLH: 1250
mg/m
3
TWA: 2.5 mg/m
3
respirable
dust
1-Propene, 1,1,2,3,3,3-hexafluoro-,
polymer
with
1,1-difluoroethene
9011-17
-0
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
TWA:
2.5 mg/m
3
dust
(vacated)
TWA: 2.5
mg/m
3
Phosphate(1-), hexafluoro-,
lithium
21324-40
-3
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
TWA:
2.5 mg/m
3
dust
(vacated)
TWA: 2.5
mg/m
3